Menu structure

Display Function

Data

value

Printer hold time (is 50% PDT)

SAVE

Store data in the product data bank

PD01 ... PD09

LOAD

Load data from a product data bank

PD01 ... PD09

QUIT

Leave the extended standard menu

standard menu

Label pitch _______________________________________________________LPIT

Distance between 2 labels on the label web, measured from leading edge to leading edge. The
distance could be set manual or an automatic length measurement is also possible. In case of
automatic mode the length is measured with the INIT function. This should be normally done,
so label material could be easy changed. Only under special condition the manual mode has to
be used.
There are three different modes:

AUTO Select automatic measuring mode
A111

The automatic mode is on and a distance of 111 mm was measured

M111

The manual mode is selected and a length of 111 mm was entered.

Range: AUTO or 5 ... 999 mm.

Label contrast __________________________________________________ CONT

With this function the sensitivity of the standard label sensor could be adjusted. If AUTO is
adjusted, the machine scans automatically. The automatic modes doesn’t work with transparent
labels. In case of another type of sensor (mechanical or capacitive) the setting has to be
manual.
There are three different modes:

AUTO Select automatic measuring mode
A111

The automatic mode is on and a contrast of 111 was measured

M111

The manual mode is selected and a contrast of 111 was entered.

Range: AUTO or 1 ... 200.

Sensor status ____________________________________________________SENS

Function: Status of label sensor is indicated, i.e. there is a label in the sensor the abbreviation
LAB is displayed and GAP is shown if there is only backing material inside the label sensor.
Can be used for all sensor types i.e. mechanical or electronic ones.