Chapter 11: AI2524 Sync PPP Configuration Steps

August 1997

Page 11-15

2524UM

Configure a Router as a Callback Server

Beginning in global configuration mode, configure a router as a call
back server:

1.

Specify the interface and enter interface configuration mode.

interface serial

number

2.

Enable DDR. Set parity on synchronous serial interfaces and asyn-
chronous interfaces.

dialer in-band [no-parity | odd-parity]

3.

Enable PPP encapsulation.

encapsulation ppp

4.

Enable CHAP or PAP authentication.

ppp authentication {chap | pap}

5.

Map the next hop address to the host name and phone number,
using the name of the map class established for PPP callback on
this interface.

dialer map

protocol address

name

hostname

class

classname dial-string

6.

(Optional) Configure a dialer hold queue to store packets to be
transferred when the callback connection is established.

dialer hold-queue

number

timeout

seconds

7.

(Optional) Configure a timeout period between calls.

dialer enable-timeout

seconds

8.

Configure the interface to accept PPP callback.

ppp callback accept

9.

(Optional) Enable callback security, if desired.

dialer callback-secure

10. Return to global configuration mode.

exit

11. Configure a dialer map class for PPP callback.

map-class dialer

classname