0038 so-dimm not detected, 0039 buffer ecc error corrected, 003b rebuild paused – AMCC 3WARE 720-0138-00 User Manual

Page 134: 003c initialize paused

Advertising
background image

Chapter 9. Troubleshooting

126

3ware Serial ATA RAID Controller User Guide for the Power Mac G5

0038 SO-DIMM not detected

This message applies to the 3ware 9500S controller which has removable
memory. This message will be sent if there is no SODIMM memory
connected to the controller. In this case, the controller is inoperable and
cannot be used until a compatible SO-DIMM is put on the controller. For a list
of SODIMMs compatible with the 9500S, see

http://www.3ware.com/KB/article.aspx?id=11748

.

Other 3ware controller models do not have memory that can be removed.

0039 Buffer ECC error corrected

This message will be sent when the controller has detected and corrected a
memory ECC error.

003A Drive power on reset detected

If the controller detects that a drive has lost power and then restarted, it will
send this message. The controller may degrade the unit (if possible).

For troubleshooting information and a link to drive manufacturer diagnostic
utilities, see

http://www.3ware.com/KB/article.aspx?id=14927.

003B Rebuild paused

This message will be sent when the rebuild operation is paused.

Rebuilds are normally paused for ten minutes after a system first boots up and
during non-scheduled times when scheduling is enabled.

For more information on scheduling rebuilds, see “Scheduling Background
Tasks” on page 76

003C Initialize paused

This message will be sent when the initialization is paused.

Initializations are normally paused for ten minutes after a system first boots
up and during non-scheduled times when scheduling is enabled. Initializations
follow the rebuild schedule.

For information on the current task schedules, see “Viewing Current Task
Schedules” on page 77
.

For information on initialization, see “About Initialization” on page 69

Advertising