Chapter 6. Maintaining Units

74

3ware Serial ATA RAID Controller User Guide for the Power Mac G5

To rebuild a unit through 3DM

1

If necessary, add a new drive to replace the failed drive. (For details, see
“Adding a Drive” on page 58.)

2

In 3DM, choose

Management > Maintenance

.

3

In the

Unit Maintenance

section of the Maintenance page, select the

degraded unit and click the

Rebuild Unit

button.

4

When a dialog box displays available drives, select the drive you want to
replace the failed drive and click

OK

.

Figure 28. Selecting a Drive when Rebuilding

5

If the degraded unit has more than one failed drive (for example, a RAID
10 where both mirrored pairs each have a failed drive), repeat step 3 and
step 4.

If rebuild scheduling is not enabled on the

Scheduling

page, the rebuild

process begins almost immediately in the background. If rebuild
scheduling is enabled, the unit will not start actively rebuilding until the
next scheduled time.

Note:

If a rebuild fails, check the Alarms page for the reason. If there was an ECC

error on the source disk, you can force the rebuild to continue by checking the
Overwrite ECC Error policy on the Controller Settings page in 3DM and then
running Rebuild again. This will cause uncorrectable blocks to be rewritten, but the
data may be incorrect. It is recommended that you execute a file system check
when the rebuild completes.

On Mac OS X, you can do this using the First Aid tab in

the Disk Utility—select the disk on the left and then click Verify Disk. If verification
encounters problems, you can then use the Repair Disk option on the same
screen.

Note:

If you need to cancel a rebuild, you can do so by using the

Remove Drive

link on the Maintenance page to remove the drive from the unit.