0043 Backup DCB read error detected

This message will be sent when the controller sees a latent error in the backup
Disk Configuration Block (DCB). A scrubbing activity will be started to
repair any sector errors on getting this error. An effort is made to read the
backup DCB even when the primary DCB is successfully read. When an error
occurs here, this is a latent error that needs to be addressed before any future
errors so this DCB is re-written with the primary copy to rectify the errors
found.

If this error occurs, we recommend verifying the unit. See “Starting a Verify
Manually” on page 72
.

0044 Battery voltage is normal

The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage falls outside the acceptable range then
comes back within the acceptable range, this message will be posted to the
host.

0045 Battery voltage is low

The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is below the warning threshold, this message
will be posted. When this event happens, the Battery Backup Unit is still able
to backup the 3ware RAID controller, but you should replace the battery.

0046 Battery voltage is high

The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is above a warning threshold, this message
will be posted. When this event happens, the Battery backup Unit is still able
to backup the 3ware RAID controller but you should replace the battery.

0047 Battery voltage is too low

The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is too low to operate, this message will be
posted. This indicates that the battery pack must be replaced. The Battery
Backup Unit becomes not ready and is unable to backup the 3ware RAID
controller.

0048 Battery voltage is too high

The Battery Backup Unit measures and evaluates the battery pack voltage on
a continuous basis. If the voltage is too high to operate, this message will be
posted. The Battery Backup Unit becomes not ready and is unable to backup