Enclosure led status indicators, Unit statuses, Enclosure led status indicators unit statuses – AMCC 3WARE 720-0138-00 User Manual

Page 71

Advertising
background image

Checking Unit and Drive Status

www.3ware.com

63

Enclosure LED Status Indicators

The LEDs on your enclosure also provide status information about your
drives and units.

Unit Statuses

The following is a list of unit statuses you may see in 3DM:

OK.

The unit is optimal and is functioning normally.

Rebuilding.

The unit is in the process of writing data to a newly added

disk in a redundant unit, in order to restore the unit to an optimal state.
The unit is not fully fault tolerant until the rebuilding is complete. For
more information, see “Rebuilding Units” on page 73.

Rebuild-Paused.

The unit is set to rebuild, however scheduling is

enabled, and the present time is not during a scheduled timeslot.
Rebuilding will start at the next scheduled time slot. Rebuilds are also
paused for up to ten minutes after a reboot, even during a scheduled
timeslot.

Table 8: Meaning of LED Colors and Behavior

Color

Drive Status

Solid green

OK

Blinking green

Identify

This occurs when you have used the Identify command in 3DM
to locate a particular drive or unit. (See “Locating a Drive by
Blinking Its LED” on page 81
.)

Black

No drive

Solid Amber

Hot spare

Blinking amber

Rebuilding

The drive in this slot is part of a RAID unit that is currently
rebuilding. You can continue to use the unit. For more
information, see “Rebuilding Units” on page 73.

Solid red

Drive fault

This drive has failed. You should replace it and rebuild the unit.

Blinking red

Predicted drive fault

3ware software predicts that this drive will fail soon. You may
want to replace it.

Advertising