0055 battery charging started, 0056 battery charging completed, 0057 battery charging fault – AMCC 3WARE 720-0138-00 User Manual

Page 139: 0058 battery capacity is below warning level, 0059 battery capacity is below error level, 005a battery is present, 005b battery is not present, 005c battery is weak

Advertising
background image

Error and Notification Messages

www.3ware.com

131

0055 Battery charging started

This message is posted when the Battery Backup Unit starts a battery charge
cycle.

0056 Battery charging completed

This message is posted when the Battery Backup Unit completes a battery
charge cycle.

0057 Battery charging fault

This message is posted when the charger of the Battery Backup Unit has
detected a battery fault during a charge cycle. The Battery Backup Unit
becomes not ready and is unable to backup the 3ware RAID controller.

0058 Battery capacity is below warning level

The measured capacity of the battery is below the warning level. When this
occurs the Battery Backup Unit is still able to backup the 3ware RAID
controller but it signals that the battery pack should be replaced soon.

0059 Battery capacity is below error level

The measured capacity of the battery is below the error level. When this
occurs the Battery Backup Unit becomes not ready and is unable to backup
the 3ware RAID controller. You must replace the battery pack.

005A Battery is present

This message is posted to the host when the Battery Backup Unit detects that
a battery pack has been connected.

005B Battery is not present

This message is posted to the host when the Battery Backup Unit detects that
the battery pack has been removed.

005C Battery is weak

The Battery Backup Unit periodically evaluates the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.
This message is posted when the result of the health test is below the warning
threshold. This indicates that the battery pack should be replaced soon
because the battery is becoming weak.