Silent install did not execute successfully, Task bar menu does not clear – HP UPS Management Modules User Manual

Page 99

Advertising
background image

Troubleshooting 99

Action: Refer to the Microsoft® Knowledge Base article 819760.

Shutdowns not functioning when Any Server is
configured in a redundant configuration

Action: Reconfigure the management server information on the agent.

1.

Open the agent configuration program for your operating system.

o

Windows ("

Reconfiguring the agent on Windows operating systems

" on page

34

)

o

Linux ("

Reconfiguring the agent on Linux operating systems

" on page

38

)

o

HP-UX ("

Reconfiguring the agent on HP-UX operating systems

" on page

40

)

2.

Enter the correct IP address, host name, communications port, or serial path for the first management
server that should communicate with the agent. Do not select Any Server from the dropdown box in
Windows or enter an asterisk (*) where prompted for Linux or HP-UX.

3.

Enter the correct IP address, host name, communications port, or serial path for the second
management server that should communicate with the agent. Do not select Any Server from the
dropdown box in Windows or enter an asterisk (*) where prompted for Linux or HP-UX.

4.

Close the configuration program.

Silent install did not execute successfully

Action:

Verify the command line parameters are correct.

Verify the configuration .ini file is valid.

Verify the Setup.iss destination path is correct.

Refer to the InstallShield Knowledge Base article 101901 for the setup.log result code.

Task Bar menu does not clear

Symptom: The task bar menu does not clear when clicking off the menu onto the Windows® desktop.
Possible Cause: This is a known Windows® behavior.
Action: Start another application or open a new window, and the issue disappears.

UPS Power Protection Agent does not display a
shutdown warning message in SLES operating
systems

Action: The shutdown executes correctly although a countdown does not appear.