HP Surestore 64 Director Switch User Manual

Page 107

Advertising
background image

show 95

CLI Com

m

a

nds

Output

The switch attributes data is displayed as a table that includes the following properties.

Output Example

The output from the show.switch command displays as follows.

Switch Information

State: Online

BB Credit: 2

R_A_TOV: 20

E_D_TOV: 4

Preferred Domain Id: 1

Switch Priority: Default

Rerouting Delay: Enabled

Operating Mode: Open Systems

Interop Mode: Open Fabric 1.0

Active Domain Id: 1

World Wide Name: 10:00:08:00:88:00:21:07

State

The state of the switch (for example, online or offline).

BB Credit

The BB credit as set in the config.switch.bbCredit command.

R_A_TOV

The R_A_TOV as set in the config.switch.raTov command.

E_D_TOV

The E_D_TOV as set in the config.switch.edTov command.

Preferred Domain Id The domain ID as set in the config.switch.domainId command.

Switch Priority

The switch priority as set in the config.switch.priority command.

Rerouting Delay

The rerouting delay as set in the config.switch.rerouteDelay command.

Operating Mode

The operating mode (Open Systems or S/390). This attribute cannot be
configured through the command line interface.

Interop Mode

The interoperability mode as set in the config.switch.interopMode command.

Active Domain Id

The active domain ID of the switch. This ID may or may not be the same as
the preferred domain ID.

World Wide Name

The world-wide name for the switch.