HP Surestore 64 Director Switch User Manual

Page 119

Advertising
background image

Appendix 107

Appen

d

ix

Error 213: Number of Zones Is
Zero

The config.zoning.activateZoneSet command tried to activate
the work area; however, the work area is empty. Enter the
changes in the work area, and then reenter the
config.zoning.activateZoneSet command to activate the work
area to the fabric.

Error 214: A Zone Contains
Zero Members

The config.zoning.activateZoneSet command tried to activate
the work area; however, the zone in the work area is empty. Add
at least one zone member to the zone, and then reenter the
config.zoning.activateZoneSet command to activate the work
area to the fabric.

Error 215: Zone Set Size
Exceeded

Error 216: No Attached Nodes
Exist

Error 217: All Attached Nodes
Are in the Zone

Error 218: Invalid Port Number

Error 219: Invalid Port Type

Error 222: Invalid SNMP
Community Index

The value entered for the SNMP community index is invalid. The
SNMP community index must be an integer in the range 1–6.
Enter an integer in the range 1–6.

Error 223: Unknown Error

Error 224: Invalid Argument

The value entered for a parameter of the command is invalid. For
example, a letter may have been entered where an integer is
required. Enter a valid parameter for the command as described
in Chapter 2, CLI Commands.

Error 225: Argument Does Not
Contain All USASCII
Characters

Error 226: Argument Is Too
Long

Error 227: Invalid SNMP
Community Name

Message

Cause/Solution

Advertising