HP Surestore 64 Director Switch User Manual

Page 91

Advertising
background image

show 79

CLI Com

m

a

nds

Output

The event log data are displayed as a table that includes the following properties.

Output Example

The output from the show.eventLog command displays as follows.

Date/Time Code Severity FRU Event Data

---------------- ---- -------- ----- -----------------------------------

04/12/01 10:58A 375 Major CTP-0 00010203 04050607 08090A0B 0C0D0E0F

04/12/01 09:58A 385 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F

04/11/01 07:18P 395 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F

Date/Time

The date and time when the event occurred.

Code

The event reason code.

Severity

The severity of the event. The values are:
Major—Unit operational (major failure).
Minor—Unit operational (minor failure).
Severe—Unit not operational. The causes are either the switch contains no
operational SBAR cards or the system shutdowns due to CTP thermal
threshold violations.
Info—Unit operational (information only).

FRU

The FRU and FRU position, where applicable.

Event Data

The 32-byte hexidecimal description of the event in words.

Advertising