background image

74 perf

Output Example

The output from the perf.errors command displays as follows.

Port Prim Seq Err Disc Frms Inv Tx Wrds CRC Errs Delim Errs Addr Id Errs

---- ------------ --------- ----------- -------- ---------- ------------

0 0 0 0 0 0 0

1 0 0 1284899 1 0 0

2 0 0 0 0 0 0

3 0 0 0 0 0 0

4 0 0 8 0 0 0

5 0 0 0 0 0 0

6 0 0 305233444 0 0 0

7 0 0 0 0 0 0

8 0 0 456 0 0 0

9 0 0 0 0 0 0

10 0 0 0 0 0 0

11 0 0 0 0 0 0

12 0 0 0 0 0 0

13 0 0 0 0 0 0

14 0 0 123527 21 0 0

15 0 0 0 0 0 0

CRC Errs

The number of frame CRC errors detected by the port.

Dlim Errs

The number of invalid frame delimiters (SOF or EOF) received by the port.

Addr Id Errs

The number of frames received with unknown addressing.