Restrictions on initiator/external mix mode – HP StorageWorks XP Remote Web Console Software User Manual

Page 120

Advertising
background image

120 Remote command devices

2.

Stop accessing the remote command device.

3.

Delete the remote command device mapping.

4.

Change the port block setting from Initiator/External MIX mode to Standard mode.
For the procedure to change the port block setting, see the HP StorageWorks LUN Configuration and

Security Manager XP user guide for the XP12000/XP1000/SVS200.

Restrictions on Initiator/External MIX mode

Restrictions on Initiator/External MIX mode are:

Restrictions on High Speed mode are also restrictions on Initiator/External MIX mode. For High Speed

mode the restrictions, see the HP StorageWorks LUN Configuration and Security Manager XP user

guide for the XP12000/XP1000/SVS200.

A point-to-point connection is not available.

You cannot set Initiator/External MIX mode on external ports of the Standard mode that have already

been used to map the external LUs. You cannot set Standard mode on the port of the Initiator/External

MIX mode that has already been used to map the remote command device. You must delete the

external volume’s mapping, and then change the port mode’s setting.

Using a port of the Initiator/External MIX mode, the command device of the external array can only

be recognized by the discovery operation and mapped. Other volumes cannot be recognized by the

discovery operation or mapped using the port of the Initiator/External MIX mode.