122 Troubleshooting External Storage XP

Unknown

Status: The path status is unknown.
Corrective action: The path status cannot be

identified. Contact your HP account support

representative.

Blockade

Status: The external port is blocked.
Corrective action: The external port is blocked

because of the microprogram or package

replacement or some other factor. Check the local

array’s status. If you cannot restore the path, contact

your HP account support representative.

External device setting

changed

Status: The external array’s configuration changed.

For example, the path definition was deleted, or the

external array itself was replaced by another

device.
Corrective action: The external array’s port is

recognized. See the internal array’s documentation,

and check if the operation that changes the mapped

device’s setting information has not been

performed.

LDEV size reduced

Status: The external array’s volume capacity setting

changed (was reduced).
Corrective action: Check the volume capacity of the

external array’s LU. Execute the Delete LU

operation, and retry the Add LU operation.

Not ready

Status: The reply from the external array was

NOTREADY. The external array’s drive is spinning

up, or the external array’s device is being

formatted.
Corrective action: The path cannot be used to

access the external array. Check the external

array’s status. If you cannot restore the path, contact

your HP account support representative.

Illegal request

Status: The reply from the external array was

ILLEGALREQUEST. The command cannot be

executed to the external array’s device. Data

protection might be set on the external array’s

device.
Corrective action: The external array’s port is

recognized. Check the external array’s setting. If

you cannot restore the path, contact your

HP account support representative.

Command aborted

Status: The reply of the external array was

ABORTEDCOMMAND. An error might have

occurred on the external array side.
Corrective action: The port of the external array is

recognized. Check the external array’s setting and

the condition of the connection to the external array

(for example, cables or switches). If you cannot

restore the path, contact your HP account support

representative.

Table 12

General External Storage XP troubleshooting (continued)

Error

Corrective action