LU’s capacity and each emulation type’s normal size. When mapping an external LU using emulation

types other than OPEN-V, an XP array management information area is required in the mapped LU.

This means that the capacity available after mapping is slightly smaller than the actual external LU

capacity. Available capacity decreases by the size of the XP array management information area,

and all prior data must be considered lost. For more information, see the HP StorageWorks Flex Copy

XP user guide.

Figure 12

shows an example where the external LU’s original capacity is larger than (or a multiple of)

the normal size of the local array’s emulation type (OPEN-3 in this example). Therefore, in this

example, the local array can realize two fully-sized OPEN-3 LDEVs, with some space (insufficient to

create a full OPEN-3) left over.

Figure 12

External LU capacity is larger than the specified emulation type’s basic capacity (OPEN-3

example)

Figure 13

shows an example where the external LU’s original capacity is smaller than the normal size

of the local array’s emulation type. In this example, since the resulting space is insufficient to create a

local array OPEN-3 LDEV, you can designate it as either a local array OPEN-V or an OPEN-3 CVS

LDEV. If the external LU were an XP of OPEN-3 emulation type, forfeiting a small amount of

management space would also result in an OPEN-3 CVS volume or an OPEN-V.

Figure 13

External LU capacity is smaller than the specified emulation type’s basic capacity

IO Suppression mode can only be selected when the volume being mapped is set to the OPEN-V

emulation type. If a different emulation type is set, IO Suppression mode is automatically set to Disable.

If you use the mapped external LU from the host connected to the local array, set the IO Suppression

mode to Disable when mapping the LU. For External Storage XP, select Disable. For Flex Copy XP, select

Enable.

If you use the mapped external LU for the copy source or copy destination volume for a Flex Copy XP

pair, set the emulation type to OPEN-V when mapping the volume.

If you use the mapped external LU for the copy source or copy destination volume for a Flex Copy XP

pair, set IO Suppression mode to Enable when mapping the volume.