HP StorageWorks XP Remote Web Console Software User Manual

Page 125

Advertising
background image

External Storage XP user guide 125

Backoff

Status: The reply from the external array was

Backoff. The path status is Waiting for Recovery

because a temporary error occurred in the external

array’s volume. Even if the primary path’s status

becomes Backoff, the primary path does not change

to the alternate path immediately. After error

recovery, the status becomes Normal.
Corrective action: If you cannot recover the status

from the error, the path status changes to another

status. Take the corrective action for the new path

status. If you cannot restore the path, contact your

HP account support representative.

The Discovery operation

cannot be performed.

Correct the error and retry the operation.
The source of the error could be one of the following:

Command View XP or XP Remote Web Console is not in Modify mode.

The local array port and external array port are not connected using FC

cables.

Port security is improperly set on the external array.

The status of the device in the external array is not Normal.

The external array is not connected to a local array port set to External.

The external LUN of the local array does not have a status of Normal.

The external LU capacity is insufficient (less than 46.86 MB).

The cable to the switch is not properly connected.

The zoning for the switch is not set properly.

If none of these correct the problem, disconnect and then reconnect the cable

between the local array and external array. After 30 seconds, retry the

operation.

The external LU is blocked.

Correct the error and retry the operation.
The source of the error could be any one of the following:

All set paths are blockaded (or not connected).

The external LU’s attribute is not set to Read/Write.

The external LU is blockaded by an error.

The Check Paths & Restore

Vol. command has executed

and you have waited more

than 10 minutes, but the

device’s status does not

change from Checking.

Click Refresh (

) on the Command View XP or XP Remote Web Console pane

to update the displayed information. If the device status remains Checking, even

though you updated the information, execute the Check Paths & Restore Vol.

command again.
If the problem persists despite retrying, contact your HP account support

representative.

The Disconnect Subsystem or

Disconnect Volume command

has executed, but the

progress status information is

not updated.

Click Refresh (

) on the Command View XP or XP Remote Web Console pane

to update the displayed information. If the progress information for the Cache

Destage status is not updated, even though you updated the information contact

your HP account support representative.

NOTE:

The time required to write of data from cache to the external LU

(destaging processing) depends on the volume capacity (more time is required for

a larger volume than a smaller one). The processing speed is about 20 MB/s.

However, processing speed depends on the external array’s performance and

status.

Table 12

General External Storage XP troubleshooting (continued)

Error

Corrective action

Advertising
This manual is related to the following products: