HP StorageWorks XP Remote Web Console Software User Manual

Page 124

Advertising
background image

124 Troubleshooting External Storage XP

Cannot detect port

Status: The path was removed or the external

array’s port cannot be found. There is a problem

with the connection to the external array. The

following are possible causes:

The fibre cable is not connected properly.

The topology setting between the external and

target ports does not match.

Because security is set on the port, the external

array’s device cannot be recognized from the

local array.

If the external array is connected through

switches, the switches’ settings might not be

appropriate.

Corrective action: Check the condition of the

connection to the external array. If you cannot

restore the path, contact your HP account support

representative.

Internal error

Status:

A program error occurred, or there is a

logical contradiction.
Corrective action: Contact your HP account support

representative.

Timeout

Status: Processing was retried because an abnormal

reply (Response) was returned, but processing has

stopped due to a timeout.
Corrective action: The external array’s port of is

recognized. Check the condition of the connection

(for example, cables and switches) to the external

array. If you cannot restore the path, contact your

HP account support representative.

Target error

Status: An error, such as blockade of the controller,

was found in the external array’s port.
Corrective action: Check the status of the external

array’s ports. If you cannot restore the path, contact

your HP account support representative.

Unavailable

Status: The reply from the external array was

Unavailable. The external array requested a change

to the connected port. When the status becomes

Unavailable, the primary path changes to the

alternate path that is in Standby status. When the

primary path changes, the path status becomes

Normal.
Corrective action: If the path does not change

properly, check the external array’s status. If you

cannot restore the path, contact your HP account

support representative.

Table 12

General External Storage XP troubleshooting (continued)

Error

Corrective action