Managing cache with external storage

Determining if the cache mode is disabled

If you have an existing configuration and need to determine if your external LUs are configured with cache

mode disabled, follow this procedure:

1.

In the XP Remote Web Console main pane, click the External Storage button in the left pane. The LU

Operation pane appears.

2.

In the Device tree, select an external device group.

3.

In the Device list, check the Cache Mode setting (

Figure 19

). If cache mode is enabled, you should

change it to Disabled.

Figure 19

LU Operation pane, Cache Mode setting

Changing the cache mode

If you need to change the cache mode for existing external LUs, you must delete and remap the external LU

path and definition.

CAUTION:

Before you delete any LUs that you want to remap, carefully record necessary configuration

information. If you remap existing LUs with changed configuration settings (other than cache mode), you

can lose access to the LUs and the data they contain.

Collecting device information

Before you remap an external storage device, collect the following information for each device:

LU number in the group

Universal Unique ID (UUID)

Path settings

CVS settings

Mapped location

External group number

CU:LDEV identifier

To collect each of these items: