Changing a defined alternate path priority – HP StorageWorks XP Remote Web Console Software User Manual

Page 108

Advertising
background image

6.

Click Apply. A confirmation message appears.

7.

Click OK.

The alternate path defined in the Path Setting window is applied to the local array, and the
specified contents appear in the Device list.

If errors occur during alternate path operations, failed settings and error codes appear in the
Preset list. To check error messages, right-click the failed setting, and select Detail.

Changing a defined alternate path priority

To change the alternate path's priority, use the Priority Up and Priority Down commands displayed
in the Path Setting window (

Figure 52

).

Priority Up: Raises the priority of the path selected in the Alternate Path list.

Priority Down: Lowers the priority of the path selected in the Alternate Path list.

As long as the external array uses Symmetrical Active/Active controllers (for example, XP), change
an alternate path to the currently used path by simply raising the priority of the alternate path or
lowering the priority of the currently used path.

1.

Select the LU Operation tab. The LU Operation pane appears.

2.

In the Device tree, select the external LU group number. Information about the external LU mapped
as an internal LDEV appears in the Device list.

3.

In the Device list, right-click the external LU, and select Path Setting. The Path Setting window
(

Figure 51

) appears.

4.

Detailed information about the currently used path and alternate path appears in the Configured
Paths table, and paths that can be defined as alternate paths appear in the Available Paths table.

Configuring external LUs

108