Miracle steamer, Operation (continued) – Antunes, AJ MS-150/155 User Manual

Page 12

Advertising
background image

MIRACLE STEAMER

12

P/N 1010699 Rev. M 12/06

UP

DOWN

PRGM

START/STOP

READY

1500

The amount of steam produced by your Miracle

Steamer depends on the amount of water sprayed onto

the steam generator.
Flooding of the generator may occur if the H2O setting

is set too high. To prevent flooding, the Shot Interval

Time (SHO) can be increased to allow more time for

generator heat recovery. Adjustments should be made

to both values to determine the optimum settings for

your cooking needs.
To program the control, refer to Figure 6 and follow the

procedure below:
1. Turn the unit on. The unit displays the factory

programmed Total Cycle Time in minutes and

seconds (Item A, Figure 6).

2. Press and release change the control from

OPERATION to PROGRAM mode.

3. To change the Total Cycle Time in minutes, press

▲ or ▼ to change the time (Item B, Figure 6).

4. Press and release again, and press ▲ or ▼

to change the Total Cycle Time in seconds (Item

C, Figure 6).

5. To change the SHO factory settings, make sure

the control is in PROGRAM mode, then press

and hold both ▲ and ▼ simultaneously for 1-2

seconds and then release. SHO will be displayed

(Item D, Figure 6).

6. Press and release and then press ▲ or ▼ to

change the SHO in seconds (Item E, Figure 6).

NOTE: 20 seconds is recommended.

Figure 6. Control Programming Sequence

UP

DOWN

PRGM

START/STOP

READY

15

UP

DOWN

PRGM

START/STOP

READY

00

UP

DOWN

PRGM

START/STOP

READY

SHO

UP

DOWN

PRGM

START/STOP

READY

00

UP

DOWN

PRGM

START/STOP

READY

20

UP

DOWN

PRGM

START/STOP

READY

H20

UP

DOWN

PRGM

START/STOP

READY

A. Total Cycle Time

E. SHO Time in Seconds

F. SHO Time in Minutes

G. H

2

O Cycle

H. H

2

O Setting

B. Total Cycle Minutes

C. Total Cycle Seconds

D. SHO Cycle

7. Press and release again and press ▲ or ▼ to

change the SHO in minutes (Item F, Figure 6).

NOTE: 00 minutes is recommended.

8. Press and release the Program button again and

H

2

O will be displayed (Item G, Figure 6).

9. To change the H

2

O (Steam Shot time), press

and release the Program button again to display

the setting (Item H, Figure 6). Use ▲ or ▼ to

increase or decrease the time.

NOTE: Recommended settings are:

MS-150/155/355 (0_80) 120 Volt units only

MS-250/255 (0_40) 120 Volt units only

MS-150/155/355 (1_00) 208-240 Volt units only

MS-250/255 (0_70) 208-240 Volt units only

10. Press either the Start/Stop, Single Shot, or

Operate buttons to store the changes, exit the

PROGRAM Mode and initiate the cooking cycle.

NOTE: The Start/Stop, Single Shot, or Operate but-

tons may be pressed at any time during program-

ming to store the changes and exit the PROGRAM

Mode.

NOTE: If a change is not made within 5 seconds

at any time during the programming process, all

changes made up to that point are stored in memo-

ry and the control reverts to the OPERATION Mode.

OPERATION (continued)

Advertising