MIRACLE STEAMER

20

P/N 1010699 Rev. M 12/06

Problem

Possible Cause

Corrective Action

Unit heats but there

is little or no steam

produced

and/or

The product requires

more steaming than

usual.

Water Line Valve is closed (MS-

250/255).

Check that the Water Line Valve is Open

Filter Strainer is restricted.

Check and clean the Filter Strainer as described in

the Maintenance section of this manual.

Quick disconnect is not fully

engaged at rear of the unit or is

damaged (MS-250/255).

Remove and reengage the Quick Disconnect firmly

until a “click” is heard. Replace if damaged.

Low or no water pressure in the

water line (MS-250/255).

Remove the Quick Disconnect Insert from the rear

of the unit. While holding over an empty cup, press

the white plastic tip. Strong, steady water flow

should be noted. If so, reengage firmly into unit. If

not present, or pressure is low, contact your mainte-

nance person or plumber.

Improper water pressure to unit (MS-

250/255).

Verify that a Water Pressure Regulator is installed

and set to 20-25 PSI.

Unit is not being cleaned properly

(daily/monthly).

Clean unit daily and monthly as described in the

Maintenance section of this manual.

Programming and/or SHO, H2O val-

ues were adjusted/changed improp-

erly.

Reprogram the SHO and H2O values as described

in the Programming section of this manual.

Insufficient or excessive calcium/

mineral deposits on the Generator

surface.

Verify that thin layer of calcium/mineral deposits

is present on the Generator surface. Refer to the

Maintenance section of this manual.

Generator surface is bare.

Generator surface must have a thin calcium/min-

eral coating for proper steaming. Refer to the

Maintenance section of this manual.

Generator Steam Ports are restrict-

ed.

Clean the Steam Ports as described in the

Maintenance section of this manual.

Generator Cover is warped or loose. Verify that the Generator Cover wingnut is tight. If

noticeable steam escapes around the Generator

Cover, replace the cover.

Generator Diffuser is missing.

Install Generator Diffuser or replace if missing.

Generator surface temperature is too

low.

Verify Generator surface temperature to be 380-

420° F (193 - 215° C).

Excessive con-

densation in Food

Compartment.

Water pressure is too high (MS-

250/255).

Verify that the Water Pressure regulator is set to 20

- 25 PSI. Adjust accordingly.

Programming and or SHO and H2O

values were adjusted improperly.

Reprogram the SHO and H2O values as described

in the Programming section of this manual.

Steam coming out

around top covers or

sides.

Generator Cover’s wingnut is loose.

Tighten wingnut.

Generator Cover is warped.

Replace Generator Cover.