Figure 4. Connecting Water Supply to MS-250/255

INSTALLATION (continued)

Models MS-250/255

These models require a direct cold water hookup. A

Water Inlet Hose and Strainer Assembly (Figure 4) is

supplied.

NOTE: Incoming water is controlled by a normally

closed (NC) solenoid valve located inside the

Steamer’s electrical housing.

1. Turn off the water valve (not supplied) that sup-

plies water to the unit (Figure 4).

2. Connect the 1/4” (6.5 mm) I.D. Flexible Tubing to

the outlet side of the Water Pressure Regulator

and secure using the worm clamp as shown in

Figure 4.

NOTE: A Water Pressure Regulator must first be

installed as shown in Figure 4. Failure to do so will

result in poor steaming and possible flooding. For

a single steamer, use Water Pressure Regulator P/N

7000314. For two adjacent steamers, use Water

Pressure Regulator P/N 7000235.

CAUTION

Water pressure must not exceed 30 psi (2.1 kg/

cm2 or 207 kPa). Higher water pressures may

cause poor performance or flooding. To reduce

water pressure, install a water pressure regulator,

and set water pressure to 20-25 psi (1.4 - 1.7 kg/

cm2 or 138 - 172 kPa).

3. Turn the water valve on.

4. Over a bucket, press and hold the white plastic

tip on the Quick Disconnect Insert (Figure 4) until

good, steady water flow is noted (this will purge

all air out of the line). Release and note the pres-

sure on the Water Pressure Regulator gauge. It

should read 20-25 PSI. If it reads more or less,

adjust the pressure by pulling the black knob

upwards and turning it clockwise to increase or

counter-clockwise to decrease the water pressure.

Push the knob down to lock it in place.

NOTE: When adjusting the knob, you must relieve

the existing pressure by pressing the white plastic

tip on the Quick Disconnect Insert for 3 seconds.

This allows the newly set pressure to register on

the gauge. Repeat this until the gauge reads 20-25

PSI.

5. Push the Quick Disconnect Insert into the fitting at

the rear of the unit until a “click” is heard

(Figure 4).

Connect Quick

Disconnect

Insert Here

Inlet Hose & Strainer

Assy. (Supplied)

Optional Water Pressure Regulator

with Strainer (P/N 7000314)

Shut Off Valve

(Not Supplied)

Cold

Water

Flow

Flexible Nylon Braided

1/4 " I.D. Tubing (Not Supplied)

Quick

Disconnect

Insert

Worm

Clamp

NOTE: The use of only one strainer is

acceptable instead of two.