Miracle steamer, Troubleshooting (continued) – Antunes, AJ MS-150/155 User Manual

Page 21

Advertising
background image

MIRACLE STEAMER

21

P/N 1010699 Rev. M 12/06

Problem

Possible Cause

Corrective Action

Unit floods overnight and/or

continues to steam even when

in idle mode.

Solenoid Valve is leaking due to

debris trapped inside the plung-

er (MS-250/255).

Attempt to flush the debris out of the valve

by rapidly operating the unit on a number of

“single shot” cycles and then letting it rest. If

the unit still leaks, disassemble the Solenoid

Valve and clean out the plunger. Reassemble

unit and test. If a leak is still present, replace

the Solenoid Valve. Contact your maintenance

person or Authorized Service Agency.

Solenoid Valve is installed incor-

rectly (MS-250/255).

If the Solenoid Valve was replaced, verify that

the “IN” and “OUT” labels on the valve corre-

spond to the water flow.

There is no pre-strainer or filter

on the water line just before the

unit (MS-250/255).

Equipment was supplied with a strainer. If

missing, install strainer.

TROUBLESHOOTING (continued)