MIRACLE STEAMER

31

P/N 1010699 Rev. M 12/06

WIRING DIAGRAMS

MS-150/155/250/255

MS-355

5

4

2

1

POWER

SWITCH

GND

GRN

TERMINAL

POWER

BLOCK

CORD

W

H

T

B

LK

WHT

T6

T5

SOLENOID

PUMP

OR

120V

230V

WHT

BLK

WHT

BLK

BLK

MOMENTARY

SWITCH

T1

T2

T4

#

#

ORG

BRN

BRN

BLU

GND

(PUMP ONLY)

YEL

RED

T7

T3

2

1

3+

4-

BLU

DIODE

(PUMP ONLY)

BLK

#

6

2

1

TRANSFORMER

4

5

8

10

#

# 18 GA. AWM-105°C

B

LK

/B

R

N

W

H

T

/B

LU

G

R

N

G

R

N

-Y

E

L

UNLESS OTHERWISE SPECIFIED.

NOTE: ALL WIRES TO BE 14 GA. AWM-105°C

HEATER

THERMOSTAT

HI-LIMIT

CONTROL

THERMOCOUPLE

22 GA. AWM-105°C

S.S. RELAY

BOARD

5

4

2

1

POWER

SWITCH

GND

TERMINAL

B

LK

/B

R

N

W

H

T

/B

LU

G

R

N

G

R

N

-Y

E

L

POWER

BLOCK

CORD

W

H

T

B

LK

TRANSFORMER

10

1

5

8

6

HEATER

WHT

THERMOSTAT

HI-LIMIT

CONTROL

2

4

T6

T5

THERMOCOUPLE

230V

WHT

BLK

# WHT

# BLK

BLK

MOMENTARY

SWITCH

T1

T2

T4

#ORG

#ORG

BRN

BRN

BLU

GND

YEL

RED

S.S. RELAY

T7

T3

2

1

3+

4-

BOARD

BLU

LIGHT

FLOAT SW.

BLUE

VIOLET

# BLK

WHT

DIODE

WHT

WATER

PUMP

120V

230V

WHT

BLK

#

#

2

1

4

5

120V

# 18 GA. AWM-105°C

UNLESS OTHERWISE SPECIFIED.

NOTE: ALL WIRES TO BE 14 GA. AWM-105°C

22 GA. AWM-105°C

Advertising