Miracle steamer, Troubleshooting – Antunes, AJ MS-150/155 User Manual

Page 19

Advertising
background image

MIRACLE STEAMER

19

P/N 1010699 Rev. M 12/06

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel. The unit should be unplugged when servicing,

except when electrical tests are required.

Problem

Possible Cause

Corrective Action

Control Display is Blank (power On/

Off switch is On but indicator light is

off).

The power cord is not correctly

plugged in.

Plug the power cord into the appro-

priate outlet.

The power cord and/or electrical

plug is damaged.

Inspect electrical wire, plug, and

receptacle.

The main electrical panel circuit

breaker is off or has been tripped.

Reset circuit breaker. Contact your

maintenance person or Authorized

Service Agency if it trips again.

Switch is inoperable.

Contact your maintenance person or

Authorized Service Agency for ser-

vice.

Control Display is blank (power On/

Off switch is on and indicator light is

on).

Control Board is inoperable

Contact your maintenance person or

Authorized Service Agency for ser-

vice.

Transformer is inoperable.
Loose, burnt, or broken wires in cir-

cuit.

Unit does not heat up (Control

Display is on)

Hi-Limit Thermostat is tripped or

inoperable.

Reset the Hi-Limit Thermostat

according to the Operations sec-

tion of this manual. If the Hi-Limit

Thermostat requires continuous

resetting, contact your Authorized

Service Agency for service.

Solid State Relay is inoperable.
Thermocouple is inoperable.
Control Board is inoperable.
Steam Generator is inoperable.
Loose, burnt, or broken wires in cir-

cuit.

The unit’s main electrical panel cir-

cuit breaker trips.

Damaged receptacle, plug, or cord;

a loose connection or an internal

component failure.

Turn the unit off, allow it to cool to

room temperature, and then restart

the unit. Contact your maintenance

person or Authorized Service Agency

if the condition repeats.

Water leaking inside electrical hous-

ing.

Pinhole leak in rubber hoses (MS-

150/155/355).

Replace hoses.

Loose or damaged water line tubes

and/or fittings inside electrical hous-

ing.

Tighten or replace tubes and/or fit-

tings.

ERR” appears in the Control

Display.

Programming and/or SHO and

H2O values were adjusted/changed

improperly.

Reset the Control Board as

described in the Programing section

of this manual. See Fault Codes.

Advertising