(4) Place the unit in auto-gain mode per section

2.9.1.

c. No Reticle is visible.

(1) Adjust display brightness per section 2.8.

(2) Ensure reticle is turned on per paragraph 2.12.5.

(3) Adjust reticle intensity per paragraph 2.12.4.

d. Poor or degraded image.

(1) Perform a calibration per paragraph 2.12.3.

(2) Remove night vision spectrum filter, if installed.

Clean eyepiece and objective lens.

(3) Inspect the night vision spectrum filter for dirt,

grime, scratches, and cracks. Clean and/or

replace, if necessary.

(4) Replace existing batteries with fresh batteries.

3.3 CORRECTIVE MAINTENANCE PROCEDURES

See section 3.4 of this chapter for guidance regarding

maintenance and/or repair actions beyond those described

in this manual.

3.3.1 Adjusting Throw-Lever Tension

. The throw-lever

mounting bracket has a locknut that adjusts the tension

required to clamp it to the weapon rail. It is preset at the

factory but may need adjustment when initially mounted to

the rail of the host weapon. If adjustment is required, the

following procedures apply and are performed with the

CNVD-T removed from the host weapon: