5. Starting at the cut end, measure backward and mark the break-out lengths for the
distribution cable fibers and the connector panel fibers.
6. Starting at the breakout mark, remove the protective jackets to expose the distribution
cable fibers (may be stranded or ribbon fibers) and the connector panel pigtail fibers.
7. Install the connector panel pigtail subunit and the distribution cable fiber subunit in the
splice tray and complete all splices per local practice. Refer to
then return to Step 8 to continue this procedure.
8. After splicing is completed, the splice tray cover replaced, and the excess slack rolled up,
insert the splice tray into the designated mounting slot.
9. Repeat this procedure for each connector panel pigtail subunit.
10. When all splices have been completed, re-install the rear handle assembly on the back of
each connector panel (see
).
11. Connector panel designation labels, shown in
and
, are provided on the
front door of the cabinet for recording subscriber information. For each connector panel,
indicate the subscriber address and service information and the fiber and cable number if
not specified. Splice tray designation labels, shown in
, are provided on the rear
door of the cabinet for recording distribution cable information. For each splice tray,
indicate the distribution cable and subunit number.
Figure 26. Connector Panel Designation Label - Type 1
19634-A
LABEL FOR LEFT SIDE
OF CONNECTOR PANEL #1
FRONT DOOR
REAR DOOR
1
2
3
4
19
20
21
22
37
38
39
40
55
56
57
58
SPL TRAY 1
FBR 1
SPL TRAY 1
FBR 2
SPL TRAY 1
FBR 3
SPL TRAY 1
FBR 4
SPL TRAY 2
FBR 7
SPL TRAY 2
FBR 8
SPL TRAY 2
FBR 9
SPL TRAY 2
FBR 10
SPL TRAY 4
FBR 1
SPL TRAY 4
FBR 2
SPL TRAY 4
FBR 3
SPL TRAY 4
FBR 4
SPL TRAY 5
FBR 7
SPL TRAY 5
FBR 8
SPL TRAY 5
FBR 9
SPL TRAY 5
FBR 10
PANEL
1
1-LEFT
2-LEFT
3-LEFT
4-LEFT
5-LEFT
1-RIGHT
2-RIGHT
3-RIGHT
4-RIGHT
5-RIGHT