ADCP-96-015 • Issue 1 • July 2004

Page 46
© 2004, ADC Telecommunications, Inc.

11.2 Enabling Service To a Subscriber

Use the following procedure to enable service to a subscriber:

1. Check the designation labels on the cabinet door to determine the connector panel and port

number that corresponds to the address of the subscriber.

2. Locate the subscriber port on the specified connector panel and remove both the adapter

dust cap and the connector ferrule dust cap.

3. Select and remove an unused splitter output fiber from the storage panel and carefully

work it free of any other fibers.

4. Remove the ferrule dust cap from the connector and then clean the connector as specified

in the Optical Fiber Systems Cleaning and Mating Instructions (ADCP-90-159)

5. Hold the output fiber connector near the subscriber port.

6. Use the slack storage spools on the right side of the cabinet to store any excess fiber slack

as shown in

Figure 38

.

7. Insert the output fiber connector into the connector panel port adapter.

Figure 38. Routing To Connector Panels

19639-A