Fabric resides independent of the CMM. It resides at the Back of the Chassis. CMM can fail over inde-
pendent of Switching Fabric and vice versa.

Minimum of 4 Switching Fabric Modules (SFM) with 8 ROMS chips are required to operate. The
additional SFM provides (4+1) redundancy.

FBUS is not connected to the CMMs

BBUS is connected to both the CMMs and all the NI in the chassis including the SFMs.

Up to 64 Coronados can be connected to each ROMA

Eagle Overall Block Diagram

R

R

R

R

R

R

R

R

R

R

NI

NI

NI

NI

NI

….

CMM

CMM

BBUS

Fabric Boards

FBUS

…. Secondary

…. Primary

Redundant Fabric Module