Accessing dshell on idle switches, Accessing dshell on idle switches -25 – Alcatel Carrier Internetworking Solutions 6648 User Manual

Page 45

Advertising
background image

Troubleshooting the Switch System

Dshell Troubleshooting

OmniSwitch Troubleshooting Guide

September 2005

page 1-25

NI=4 CMM=0 role=3

* state_linkA=1 remote_slotA=5 remote_linkA=51
* state_linkB=1 remote_slotB=3 remote_linkB=28

NI=5 CMM=0 role=3

* state_linkA=1 remote_slotA=4 remote_linkA=51
* state_linkB=1 remote_slotB=6 remote_linkB=52

NI=6 CMM=0 role=3

* state_linkA=1 remote_slotA=7 remote_linkA=51
* state_linkB=1 remote_slotB=5 remote_linkB=52

NI=7 CMM=0 role=3

* state_linkA=1 remote_slotA=6 remote_linkA=51
* state_linkB=1 remote_slotB=8 remote_linkB=52

NI=8 CMM=0 role=3

* state_linkA=1 remote_slotA=1 remote_linkA=51
* state_linkB=1 remote_slotB=7 remote_linkB=52

Accessing Dshell on Idle Switches

OS6600 in standalone environment is like one NI for OmniSwitch 7000 and 8000 series switches. Just
going into Dshell will allow the use of normal Vx Works commands.

There are two ways to access Dshell. One is using the dshell command from CLI or pressing control-w,
control-w (twice). The second method is used when the console or telnet is not accessible. However,
before doing so, it must be enabled by following the steps below on the primary and secondary switches:

1

From the CLI prompt enter:

->dshell

2

From the Dshell prompt enter

Certified: [Kernel]->WWON=1

output definitions

local slot number

Local stack number.

role

Either Primary, secondary or idle.

nb

Number of stacks.

loop

If redundant path is available

elements seen by link

Number of elements seen by the link with the global/local port number
as 1a, in the order they are seen and the role of each stack

NI

NI number of the switch in the stack.

CMM

CMM number of the switch in the stack. CMM number can be 65 (Pri-
mary), 66 (Secondary) or 0 (Idle). Role can be 1 (Primary), 2 (Second-
ary) or 3 (Idle).

state_link

Status of link A and B which can be 1 if up or 0 if down.

remote_slot

Remote slot number.

remote_link

Remote link number.

Advertising