Aurora Electronics MAGNETEK PVI-3600-OUTD-UK-F-W User Manual

Page 13

Advertising
background image

Installation and Operator’s Manual

Page 13 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

DC/DC Boost Converter

Grid Interface Inverter

Gate Drive Board

Gate Drive Board

Inverter

Embedded

Controller

Inverter

Embedded

Controller

Line Filter

Operator
Interface

To

Distribution
Panelboard

Breaker

Inverter Current Feedback

Grid Voltage Feedback

DC Current Feedback

Optoisolation

PMSG

Aurora Wind
Inteface Box

2 - line LCD

Reset

20 A

3.6 kW

K1

CB1

High Voltage DC Bus

PMG
input

V

oc

= 400 V max.

V

nom

= 360 V nom.

V

min

= 40

Generator Voltage Feedback

Load Bank

(Optional)

20 A

Aurora Wind Inverter

3.6 kW

Fig.4 AURORA block diagram



The block diagram shows the model AURORA PVI-3600-OUTD-UK-F-W with
its two input Dc-Dc converters. The two Dc-Dc converters are controlled in
parallel by the Wind maximum power point tracker control.

Thanks to its high efficiency and large heat-sink, AURORA offers max. power
operation over a wide ambient temperature range.
The inverter is digitally controlled by means of two independent Digital Signal
Processors (DSP), and one microprocessor.
Two single-chip independent computers maintain control in full compliance with
the electric standards relating to systems power supply and safety.
The AURORA operating system performs inter-process communication checks to
ensure the entire unit operates properly.