Page 29 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

Fig.14: Wind Input with the two input sections paralleled

NOTE: Paralleling the two input sections, the input current rating
becomes equivalent to 20A (24A short circuit).

In the parallel mode configuration the maximum input power limit is
equivalent to the max output power plus losses. It can be rated to
3800W.



WARNING: Take special care to ensure the Wind MPPT voltage
polarity corresponds to the symbols “+” and “-” labeled on the contacts
of the Wind Interface Box.
Before connecting AURORA with the Wind Interface Box, Magnetek
recommends checking, using a proper gauge, that the polarity value and
the allowable voltage value between positive and negative contacts are
correct.

Wind MPPT connection: Follow this procedure for connecting the Wind
Interface to the Aurora Wind Inverter.
1) Install the suitable wire method between AURORA Wind inverter

and Wind Interface Box.