Installing the flexnet dc, E 33, Figure 30 – Outback Power Systems GS Load Center Installation Manual User Manual

Page 35: Ge 33, Wiring

Advertising
background image

Wiring

900-0123-01-00 Rev C

33

Installing the FLEXnet DC

The OutBack FLEXnet DC (FN-DC), or a similar battery monitor, may be added to the GSLC for

observing DC current flow and providing battery state-of-charge information.

`

Figure

29

FN-DC and Wiring Block

`

Figure 30

Installing the FLEXnet DC

HUB port

Wiring block

To install the FN-DC :

1. Assemble the FN-DC wiring as shown

in the manual for the FN-DC.

Attach sense wires to FN-DC wiring

block and plug it into the FN-DC.

Plug the CAT5 cable into the port

labeled HUB.

2. Connect FNDC wiring to the GSLC.

The positive (+) and negative (-)

battery voltage sense conductors

should connect directly to the

battery bank.

The shunt sensing wires should

connect to the screws on each

shunt. It may be necessary to

remove the GS-SBUS to reach

the screws.

3. Mount the FN-DC by inserting it into

the opening to the right of the
inverter disconnects. It may be

necessary to hold it in place.

4. Secure the FN-DC with mounting

screws above and below. Tighten

until secure, but do not over-tighten.

When connecting sensing wires: The end of the shunt
connected to the GS-SBUS is the negative (–) battery

connection and should be wired accordingly. The other

end of the shunt is the “device” or “load” end and should be

wired accordingly.

See the FLEXnet DC manual for more information on these

connections. See Figure 46 on page 49 for an example of

typical system wiring.

FLEXnet DC

GS-SBUS

Shunt

screws

Shunt screws

Mounting

screws

Mounting

screws

Advertising