This water heater may be converted to a direct-vent (sealed combustion) appliance by installing
an adapter (Part No. 9007668005 (TM-DV32)) which will bring all required combustible air from
outside the building. When installing the direct-vent conversion kit, please follow all instructions
included with the kit.

 The water heater must be installed in a location where the proper amount of combustible

air will be available to it at all times without obstructions.

 If used as a direct-vent appliance, the water heater requires a 4” combustible air supply

pipe. The intake pipe must be sealed airtight.

 Air supply pipe can be made of ABS, PVC, galvanized steel, corrugated aluminum,

corrugated stainless steel or Category III stainless steel.

 Change the dipswitch settings to the direct-vent system. (See diagram below)
 Sidewall venting is recommended for the direct-vent system.
 The manufacturer recommends running the exhaust vent and the intake pipe parallel.
The Direct-Vent Conversion Kit has an “INLET” mark as shown below. Do not

reverse the INLET and the EXHAUST connections when installing vent pipes.









Direct-Vent
Conversion Kit

Make sure power to the unit is
turned OFF before changing
the dipswitch settings.

Left Bank of Dipswitches

DIRECT-VENT
CONVERSION KIT

INLET” mark

7-Seg LED

Left bank of
dipswitches

Right bank of
dipswitches