SPECIFICATIONS

Natural Gas Input

(Operating Range)

Min: 24,000 Btu/h

Max: 240,000 Btu/h

Propane Input

(Operating Range)

Min: 24,000 Btu/h

Max: 240,000 Btu/h

Gas Connection

3/4” NPT

Water Connections

3/4” NPT

Water Pressure

15 - 150 psi *

Natural Gas

Inlet Pressure

Min. 5.0” WC

Max. 10.5” WC

Propane

Inlet Pressure

Min. 8.0” WC

Max. 14.0” WC

Manifold Pressure**

Natural: 2.35” WC

Propane: 3.55” WC

Weight

59 lbs.

Dimensions

H23.6”×W18.5”×D8.9”

Ignition

Electric Ignition

Electric

Supply

120 VAC / 60 Hz

Consumption

Operation

112 W

(0.93 A)

Standby

8.9 W

(0.07 A)

Freeze-
Protection

187 W

(1.56 A)

SPECIFICATIONS……………………….

INTRODUCTION…………………………

SAFETY GUIDELINES………………....

INSTALLATION…………………………..

General…………………………………

Included Accessories….……………….

Warning for Installations………………

Outdoor Installation…………………...

Indoor Installation…………………...…

Direct Intake Vent System…………….

Venting Instructions………………......

Gas Supply / Gas Pipe Sizing………..

Water Connections……………………

Pressure Relief Valve…………………

Electrical Connections……………......

Remote Controller Connections………

Pump Control Connections……………

Pump Control Mode……………………

Easy-Link System ……………………..

Multi-Unit System………………………

Initial Operation………………………..

NORMAL OPERATION………………….

Normal Operation…………………......

Flow……………………………………..

Freeze Protection System…………...

Temperature Settings………………….

Maintenance and Service………..…….

GENERAL TROUBLESHOOTING……..

OPERATING SAFETY……..……………..

APPLICATIONS………………………......

Re-Circulation…………………………..

Dual-Purpose Heating……………......

ADDITIONAL CLEARANCES……………

OPTIONAL ITEMS………...……………..

COMPONENTS DIAGRAM…………….

PARTS LIST………………………………

OUTPUT TEMPERATURE CHART……

LIMITED WARRANTY……………………

2

3

4

5

6

6

7

8

9

10

11

15

18

18

19

20

21

22

24

28

30

31

31

33

33

34

35

36

39

41

41

42

43

44

45

48

50

51

The manufacturer reserves the right to discontinue, or change at any time,
specifications or designs without notice and without incurring obligations.

*40 psi or above is recommended for maximum flow.
**The Manifold Pressure is the factory setting and

generally should not need adjustment.

Advertising
This manual is related to the following products: