Flow, Freeze protection system – State GTS-710-PIEA User Manual

Page 33

Advertising
background image

- 33 -

FLOW

 The flow rate through the water heater is limited to a maximum of 9.0 GPM.
 The temperature setting, along with the supply temperature of the water will determine the

flow rate output of the unit.

 Please refer to the temperature vs. gallons per minute chart on p. 50 to determine the likely

flow rates based on your local ground water temperature and your desired outlet water
temperature combination.

 Based on the United States Department of

Energy method of testing water heater output,
the water heater is rated for 300 gallons per
hour (GPH) or 5.0 gallons per minute (GPM)
for Natural Gas, and 318 GPH or 5.3 GPM for
Liquid Propane, when raising the water
temperature by 77

F (from 58 F to 135 F).

 Refer to the chart on the right for typical

household plumbing fixture flow rates to
determine what the water heater can do in a
household application.

FREEZE PROTECTION SYSTEM

 This unit comes equipped with heating blocks to protect it against damages associated with

freezing.

 For this freeze protection system to operate, there has to be electrical power to the unit.

Damage to the heat exchanger caused by freezing temperatures due to power loss is not
covered under the warranty. In cases where power losses can occur, consider the use of a
backup power supply.

 The freeze protection system will activate when the surrounding and/or outside temperatures

drop below 36.5 °F (2.5 °C).

 In any areas subject to freezing temperatures, the manufacturer highly recommends

installing the unit indoors. In such an installation, freezing issues can only occur if cold air
enters through the venting into the heat exchanger, whether by negative pressures within the
installation location or by strong outside winds. It is the installer’s responsibility to be aware
of these issues and take all preventative measures. The manufacturer will not be
responsible for any damage to the heat exchanger as a result of freezing.

 The manufacturer also highly recommends the use of a backflow preventer (sold separately)

to minimize the amount of cold air entering through the exhaust venting when the water
heater is off.

 If you will not be using your heater for a long period of time:

1. Completely drain the water out of the unit. Refer to p. 35.
2. Disconnect power to your heater.

This will keep your unit from freezing and being damaged.




Household Flow Rates

Appliance / Use

Flow Rate (GPM)

Lavatory Faucet

1.0

Bath Tub

4.0 – 10.0

Shower

2.0

Kitchen Sink

1.5

Dishwasher

1.5

Washing Machine

4.0

Taken from UPC 2006

CAUTION: Only pipes within the water heater are protected by the freeze protection system.
Any water pipes (hot or cold) located outside the unit will not be protected. Properly protect
and insulate these pipes from freezing.