OPTIONAL ITEMS

1. Temperature remote controller: 9007603005

(TM-RE30)

The temperature remote controller
has two functions. It allows the
output temperature from the water
heater to be adjusted within the
range of 100 °F to 185 °F, and it
also works as a diagnostic tool that

will give a concise error code whenever there is a
problem with the unit. The temperature options are
100 °F, 105 °F, 110 °F, 115 °F, 120 °F, 125 °F, 130 °F,
135 °F, 140 °F, 145 °F, 150 °F, 155 °F, 160 °F, 165 °F,
170 °F, 175 °F, 180 °F and 185 °F. See the
troubleshooting section for information on possible
error codes.

2. Multi-unit controller: 9007675005

(TM-MC01)

The multi-unit controller can control

a maximum of 20 water heaters,

from 24,000 BTU to 4,800,000

BTU. It also works as a diagnostic

tool that will give a concise error

code whenever there is a problem

with the unit. Usage of this

controller requires having the

9007603005 (TM-RE30) remote

controller.

3. 4” Backflow preventer and F-F adaptor:

9007996005

There are two functions available for
this adaptor which can be connected
with the water heater and NovaVent
venting line and prevents the
backflow of air through the exhaust
vent. This helps prevent harmful
exhaust gases from entering the
home, as well as helping to prevent
the unit from freezing in areas where

cold air can be blown or drawn into the exhaust
system. Install this adaptor in accordance with the
installation instructions that are packaged with the
adaptor and any applicable codes.

4. Vent cap: 9007676005 (TM-VC32)

The vent cap is for outdoor

installation with the 710 (T-M32)

water heater. The cap is

installed on the top of the unit,

instead of connecting an

exhaust vent pipe. The cap will

prevent any debris that might be in the environment

from entering the unit and causing damage or a fire

hazard, as well as preventing rain or other weather

from entering the unit.

5. Direct-vent conversion kit: 9007668005

(TM-DV32)

This kit can be used to convert the
710 (T-M32) from a conventional
vent system to a direct-vent (or
sealed combustion) system. This is
a CSA tested conversion kit. Install
this conversion kit in accordance
with the manufacturer’s installation

instructions and any applicable codes.

6. Pipe cover: 9007672005 (TM-PC32)

The pipe cover protects the plumbing

pipes to the 710 (T-M32) from

unexpected adjustments. This pipe

cover is fixed to the bottom of the

water heater, which hides the

plumbing and improves the visual

aspects of the whole installation for the water heater.

7.

Sidewall vent terminator (Hood) and Wall thimble:

They are used when venting out through the wall. These terminations are special
stainless steel vents for gas applications and are UL listed as Categoly ll, lll and lV.
For different wall thickness, there are
two ranges of lengths available.
(Refer to the NovaVent brochure
for details.) Install these vent
terminations in accordance with
their installation instructions and
any applicable local codes.

Covering wall thickness

Part #

Terminator Hood

9007999005

Wall Thimble 4 - 7 in.

9008345005

Wall Thimble 5 - 10 in.

9008346005

Termination + Thimble 4 - 7 in.

9008004005

Termination + Thimble 5 – 10 in.

9008005005

Wall Thimble

Terminator Hood