Chapter 7 ____________________________________________________________ Troubleshooting

VAISALA _______________________________________________________________________ 137

3.

If everything else seems to be functioning correctly, change the
parameter settings as follows:
- If possible, check the accumulated water sum against a

reference rain gauge This will indicate how close Rain
intensity scale
is to the optimal value. Decrease the scaling
factor if the FD12P rain amount is too high.

- Otherwise, increase DRD scale.

Have Jumper Settings Been
Changed?

If you have reason to believe that the original jumper settings have
been changed, see Appendix B on page 147.

Values for Internal Monitoring

The typical values are according to factory testing and are allowed to
be changed within the given minimum/maximum limits. For example,
the LEDI value is dependent on ambient temperature of more than

+25 °C and aging of the IR-LED.

The fault limits give hints for troubleshooting.

The values for internal monitoring are listed in Table 29 on page 138.