Mes command, Ames command – Vaisala FD12P User Manual

Page 71

Advertising
background image

Chapter 4 _________________________________________________________________ Operation

VAISALA ________________________________________________________________________ 71

Command

Description

CHEC

Displays average signal

CAL Calibrator_frequency

Calibration

CLRS

Clears precipitation sums

ACAL

Analog output calibration

TIME hh mm ss

Sets/displays system time

DATE yyyy mm dd

Sets/displays system date

BAUD rate par

Baud rate setting
(Rate 300, 1200, 4800, 9600)
(Par E(7E1) or N(8N1)

AN channel

Analog channel
(0,1,3,8 ... 15 or ANALOG ID)

DAC data

(Without DATA = SWEEP)

RESET

Hardware reset by watchdog

WHIS

Present weather history

WSET

PRW reference values

DRY ON

Sets DRD dry offset

WET ON

Sets DRD wet scale

BLSC

Sets/Displays background luminance scale

MES Command

After opening the line for operator commands (see section
Entering/Exiting the Command Mode on page 61), a data message can
be displayed using the MES command. There are eight messages
available for different uses and they numbered from 0 to 7. Refer to
section Message Types on page 63 for message type descriptions.

The command format is the following:

MES Message_number

↵↵

with a valid range from 0 to 7. For example, when choosing the data
message number 2, type

MES 2

AMES Command

The AMES command defines the message, which the FD12P
transmits as the automatic message or as the default polled message.
Messages can also be displayed by the MES command, described in
MES Command on page 71.