Chapter 3 ________________________________________________________________ Installation

VAISALA ________________________________________________________________________ 35

Cable Selection

Line Power Cabling

The FD12P is supplied with a two-meter power cable. If a local
terminal for 115/230 VAC power supply is not available, use an
extended mains cable from the FD12P to the nearest power source.
This cable should be armored and of underground type. The armored
reinforcing acts as a mechanical shield and also provides protection
against lightning. Ground the cable screen at both ends.

The recommended mains wire cross sections are shown in Table 5
below for mains volta
ge 230 VAC. For 115 VAC, divide the
maximum distances by four.

Table 5

Mains Cable Selection

Maximum
Distance from
Voltage Source

One-wire
Cross-section
Area

Nearest
AWG-gauge

Typical Non-
armored Cable
Diameter

2 km

1.5 mm2

No 15 AWG

10 mm

4 km

2.5 mm2

No 13 AWG

14 mm

8 km

4.0 mm2

No 11 AWG

18 mm

NOTE

Cables with diameters more than 12 mm require a separate junction
box which is also available from Vaisala.

Communication Cable

The FD12P provides the RS-232C, RS-485, CCITT V.21 modem, and
analog transmission interfaces. Consider your needs for
communication before the installation. The communication method
depends on the distance between the computer or display and the
FD12P and the number of the FD12P sensors. Table 6 below describes
the possibilities.

Table 6

Communication Cable Lengths

Cable Length

One FD12P

Several FD12Ps on line

< 150 m

RS-232

RS-485, modem

< 500 m

RS-485, modem RS-485, modem

> 500 m

Modem

Modem