Message 4, Messages 5 and 6, Message 4 messages 5 and 6 – Vaisala FD12P User Manual

Page 66: An example of mes 6 is provided below, The status is in hexadecimal notation

Advertising
background image

User's Guide _______________________________________________________________________

66

______________________________________________________ M210296en-A

Message 4

Message 4 is for hardware monitoring. The same data line is obtained
by using the FREQ command.

0.51

126.82 0.91

15

3

5

2.7

5.6

1280 19.5

1.8

819

>FREQ

SIGNAL+

OFFSET DIST SWID MAXI OWID

TE LEDI BACKS

VBB

TS

DRD

0.59

126.83 0.91

17

2

6

2.7

5.6

1280 19.4

1.8

816

0.59

126.83 0.91

17

2

6

2.7

5.6

1280 19.4

1.8

817

Messages 5 and 6

Messages 5 and 6 are for MITRAS transmissometer message
emulation in VAISALA RVR systems.

An example of MES 5 is provided below:

"

ID 1 V

1050 CV ////// B ///// S0101

-*#

--- <CR><LF><ETX>

-- receiver 2 status

(two spaces)

-- receiver 1 status

-- transmitter status

-- S, status heading

------ background luminance value

cd/m2(option)

-- B, background luminance heading

------- (contamination) compensated visibility

(reserved, not supported by FD12P)

--- CV, compensated visibility heading

------- non-compensated visibility m

-- V, visibility heading

-- unit ID (one character only)

-- ID, start indicator

- <STX>

"

ID 1 V

1050 CV ////// B ///// S0101

-*#

1234567890123456789012345678901234567890123

An example of MES 6 is provided below:

"

ID 1 V

4550 B ///// S4101

-*#

--- <CR><LF><ETX>

-- receiver 2 status

-- receiver 1 status

-- transmitter status

-- S, status heading

------ background luminance value cd/m

2

-- B, background luminance heading

------- non-compensated visibility m

-- V, visibility heading

-- unit ID (one character only)

-- ID, start indicator

- <STX>

"

ID 1 V

4550 B ///// S4101

-*#

123456789012345678901234567890123

The status is in hexadecimal notation.