Patchswitch equipment -5, Patchswitch equipment – ADC RS-232/V24 User Manual

Page 15

Advertising
background image

ADCP-50-304 • Issue 19 • June 1999 • Section 1: Introduction

Page 1-5

© 1999, ADC Telecommunications, Inc.

2.2

PatchSwitch Equipment

The PS equipment consists of a chassis with a control module and associated power supply,
modules forpatching and/or switching and interfacing, blank panel and patch cords.

Table 1-2

lists

the PS equipment.

Table 1-2. PatchSwitch Equipment

(V.35 Modules are described in Section 3. X.21 Modules are described in

Section 4

)

ADC NUMBER

DESCRIPTION

COMMENTS

RDC-01

PatchSwitch Chassis,
16 position

Standard rack mounted chassis which includes a
control module. Requires Power Supply. Chassis can
hold up to 16 PS modules and one patch interface,
test data converter, or blank module. Provides female
DCE and DTE connectors.

RDC-02

PatchSwitch Chassis,
16 position

Same as RDC-01 except provides male DCE
connectors.

PSM-01

LED/Alarm Patch Module with
A/B Switching

A/B electromechanical switching between two data
communications devices; and computer, modem and
monitor patching functions. Also includes RS232/
V.24 LED and Alarm functions.

PSM-02

Patch Model with A/B Switching

Same as PSM-01 except no LED and alarm

functions.

PSM-03

Module with A/B Switching Only A/B electromechanical switching between two data

communications devices.

PSM-04

LED/Alarm Patch Module with
Off-Line Access

Same as PSM-01 except it provides direct test access
to off-line device when module is in either A or B
(sub) state.

PSM-05

Patch Module with Off-Line
Access

Same as PSM-04 except no LEDs or alarm.

PSM-07

LED Alarm Patch Interface

Connects one or two data ports to other test equip-
ment via patch cords. Also includes RS-232/V.24,
LEDs and alarm.

PSM-08

Patch Interface

Same as PSM-07 except no LEDs and alarm.

PSM-09

Blank Panel

Covers unused card slots.

PSM-12

RS-232/V.24 LED/Alarm
Test Module

Provides an interface port for test equipment requir-
ing RS-232/V.24 circuit compatibility. Normally
positioned in slot 17 of RDC-01 and RDC-02.
However, this PS module may be mounted in any
slot, except for 18, of the above PS chassis. Includes
eight LEDs for RS-232 lead status monitoring,
an adjustable alarm and patch jack port.

PSM-13

Test Module

Same as PSM-12 without LEDs and alarm
circuitry.

PSM-15

Control Module

Chassis control module permitting local, or
dc pulse serial remote switch and alarm control.

PSW-000001 PatchSwitch Power Supply

(6 pin in-line connector)

Dual output supply used with PSC-01/PSC-02
chassis with input power source from 90 to 240 Vac,
48-63 Hz.

Advertising