ADCP-50-304 • Issue 19 • June 1999 • Section 4: PatchSwitch X.21

Page 4-10
© 1999, ADC Telecommunications, Inc.

5

SPECIFICATIONS

Module specification are shown in

Table 4-5

.

6

INSTALLATION

Remove power to the shelf by turning off the power supply or unplugging the power supply
connected to the PatchSwitch chassis.

6.1

Interlock Jumper Installation

If an interlock option is desired for the system, the proper jumper must be connected in each A/B
Switch Module before installation in the chassis. Each A/B switch module has five interlock
positions. One jumper position for each of four interlock groups labeled 1 through 4 and one
vertical interlock group labeled V. See

Figure 4-7

for the location of the jumpers on the module.

Interlocking is used to protect the user from accidentally switching a common backup piece of
equipment onto two or more different data lines. This is accomplished by allowing only the first
module in that group to switch. The remaining modules remain in the “normal state” or the “A”
position. Modules in the “B” position once switched to “A” will remain in the “A” position.

Table 4-5. Specifications

PARAMETER

SPECIFICATIONS

REMARKS

Dimensions

H

×

W

×

D

6.95

Ч

0.94

Ч

9.82 inches

Install in RDC-01 or RDC-02 chassis

X.21 Modules

6.95

Ч

0.6

Ч

2.75 inches

Install in RDC-01 or RDC-02 chassis

Adapter Mofule

Environmental

Temperature

Operating

+32

°

to 122

°

F (0

°

to 50

°

C)

Storage

–32

°

to 158

°

F (–40

°

to 70

°

C)

Relative humidity

Operating

10 to 80%

No condensation

Storage

5 to 90%

No condensation

Power

Power Supply

+5 volts dc

PSW-000003 (ac power source)

+12 volts dc

Current Supply

200.0 ma max.