Figure 2-3 – ADC RS-232/V24 User Manual

Page 24

Advertising
background image

ADCP-50-304 • Issue 19 • June 1999 • Section 2: Functional Description

Page 2-4
© 1999, ADC Telecommunications, Inc.

A remote control device can control the operation of up to 16 full PS chassis assemblies (16
modules each) using a dedicated communications channel. This channel has four signals:

1. Transmit Data (TD)

2. Receive Data (RD)

3. Clear-To-Send (CTS)

4. Request-To-Send (CTS)

Each of the above signals has the same function as the corresponding signals defined by the RS-
232 standard.

The communications channel transmission medium is a cable consisting of four twisted wires
within an overall shield. The shield is ground potential.

Figure 2-3. Control Module, Simplified Block Diagram (Standard and Remote)

Note: The electrical characteristics of the communications channel cable (9-wire)
conform to RS-422A/V.11 (X.27) standards.

CONTROL

MODULE*

MODULE 0

SLOT 1

MASTER A/B

ENABLE

RESET

P/S

C
H
A
S
S

I

S

B
A
C
K
P

L

A
N
E

MODULE 1

SLOT 2

MODULE 15

SLOT 16

SLOT 17

P/S MODULES

2 THROUGH 14

(SLOT 3-15)

COMMUNICATIONS

CHANNEL**

TO NEXT P/S CHASSIS

REMOTE

CONTROL DEVICE

* STANDARD
CONTROL OR
REMOTE
CONTROL

** USED ONLY
BY REMOTE
CONTROL
MODULE

SLOT 18

1609-A

Advertising
This manual is related to the following products: