Figure 2-10. LED/Alarm Patch Interface Detailed Circuit Diagram

8

TEST MODULE (PSM-12)

Test Module PSM-12 provides the user with RS-232/V.24 interface capabilities, status
indicators for eight (8) leads and alarm conditions. A simplified block diagram illustrating the
test module connections is shown in

Figure 2-11

. Two female RS-232/V.24 TEST ports, located

on the rear of the test module, are available for connecting the test equipment. Another female
RS-232/V.24 port and a patch jack are located on the module front panel. All four connectors
are hardwired in parallel.

The eight RS-232/V.24 circuit leads having LED indicators are: TD; RD; DCD; SQ; RTS; CTS;
DSR; and DTR. When a monitored circuit lead is active (signal present), the associated LED
indicator turns on (only while the signal is present). The colors and signal definitions for the
applicable LED status indicators are detailed in

Table 2-4

.

An adjustable alarm circuit with associated LED (ALM), is provided to inform the user when a
preselected alarm condition exists on one of the monitored leads. Each monitored lead has a
jumper connection to the alarm circuit control logic. The alarm is user selectable for any one of
the eight leads. The RS-232/V.24 interface signal leads are defined in

Table 2-3

. The alarm

circuit control logic supplies the alarm signal to the control unit and an alarm indicator.

Note: Except for the A/B switching circuits, the circuit diagram shown in

Figure 2-6

is

applicable to PSM-12.

TOGGLE

SWITCH

TD

RD

DCD

SQ

RTS

CTS

DSR

DTR

ALM

ALM

RST

BACKPLANE

ALARM

JUMPER

STATUS

INDICATORS

PIN 2

PIN 3

PIN 8

PIN 21

PIN 4

PIN 5

PIN 6

PIN 7

PIN 20

LOWER

INTERFACE

RS-232C

LEADS

ALARM

CONTROL

MODULE

+5 Vcd

GND

STORE

AUTOMATIC

ALARM

RESET

ALARM

CIRCUIT

CONTROL

LOGIC

OFF

LED

DLY

ROTARY

SWITCH

TOUCH

SWITCH

ALARM

INDICATOR

1615-A

Advertising
This manual is related to the following products: