ADC RS-232/V24 User Manual

Page 70

Advertising
background image

ADCP-50-304 • Issue 19 • June 1999 • Section 6: Installation

Page 6-5

© 1999, ADC Telecommunications, Inc.

Table 6-1

shows the binary switch settings corresponding to the identifying PS chassis

addresses.

Some older control modules only allow addresses up to “07”. These can be identified by the
digits –7702 at the end of the part number. Models with digits –7708 or –7709 are capable of
addresses to “15”. Both can be intermixed in a system as long as the –7702 versions are
assigned addresses of “07” or below.

A switch in the ON position represents a zero (0) bit, and conversely, a switch in the down
position (not ON) represents a one (1) bit.

For example, when facing the component side of the CM circuit board, the address for the
chassis number 10 is set as shown in

Figure 6-3

.

Figure 6-3. Control Module DIP Switch Settings for Chassis 10

Table 6-1. Control Module DIP Switch Address Settings

SWITCH POSITIONS FOR BINARY ADDRESSES

PS CHASSIS

ADDRESS

1

2

3

4

On

On

On

On

00

Off

On

On

On

01

On

Off

On

On

02

Off

Off

On

On

03

On

On

Off

On

04

Off

On

Off

On

05

On

Off

Off

On

06

Off

Off

Off

On

07

On

On

On

Off

08

Off

On

On

Off

09

On

Off

On

Off

10

Off

Off

On

Off

11

On

On

Off

Off

12

Off

On

Off

Off

13

On

Off

Off

Off

14

Off

Off

Off

Off

15

1636-A