ADCP-50-304 • Issue 19 • June 1999 • Section 2: Functional Description

Page 2-17

© 1999, ADC Telecommunications, Inc.

10

PS RS-422/RS-232 INTERFACE CONVERTER MODULE (PSR-06)

The PatchSwitch module converts signals to provide RS-422/RS-232 compatibility for remotely
controlled PatchSwitch equipment, see

Figure 2-13

. Mounted in slot position 17 of the

PatchSwitch chassis, the Data Converter Module interfaces with the ADC Remote Control Unit,
CRT terminal, or computer directly, or indirectly through modems and telephone lines. The
module is a printed circuit board assembly with components, a front panel with four LED status
indicators and a rear 96-pin DIN connector. There is one eight-position programming plug
provided on the circuit board to assign the Interface Converter module as a DTE or DCE. This is
done by placing the eight position programming plug into one of two DIP Sockets labeled DTE
or DCE. There is also a two-position Berg Post to inactivate interface when Data Set Ready
(DSR) is not asserted (DTE mode only). A simple block diagram illustrating the Data Converter
connections is shown in

Figure 2-14

.

Table 2-6

lists LED status indicators.

The functions of the Data Converter status indicators (LEDs are as follows):

RSP (Respond) flashes when data is being transmitted from the control module.

CMD (Command) flashes when data is being received by the control module.

SEL (Select) turns on when any attached PatchSwitch chassis has been addressed.

CTL (Control) turns on when a control device is on-line and ready (RTS or CTS signal).

Figure 2-13. RCU to Remote PatchSwitch Chassis

RS-422

PUBLIC

TELEPHONE

NETWORK

RS-232

REMOTE

CONTROL

UNIT

PATCHSWITCH CHASSIS 0

CM 0

SLOT 18

PS MODULE

SLOT 16

PS MODULE

SLOT 1

PSR-06A

DATA CONVERTER

SLOT 17

SLOTS

2 – 15

B
A
C
K
P

L

A
N
E

RS-422 COMMUNICATION CHANNEL

TO ADDITIONAL PS CHASSIS

RS-232

MODEM

RS-232

MODEM

NOTE:
THE PSR-06A IS REQUIRED ONLY IN ONE
SWITCH CHASSIS AT EACH REMOTE LOCATION.
THE OTHER CHASSIS ALL COMMUNICATE
USING THE RS-232 COMMUNICATION CHANNEL.