Alarm jumper installation -11, Alarm jumper installation, Figure 4-7 – ADC RS-232/V24 User Manual

Page 60: 2 alarm jumper installation

Advertising
background image

ADCP-50-304 • Issue 19 • June 1999 • Section 4: PatchSwitch X.21

Page 4-11

© 1999, ADC Telecommunications, Inc.

The three classes of interlock groups available are:

1. Global Interlock: Groups 1 and 2 are global and may be extended to all chassis in a

system, using a 20-pin interchassis interlock cable. With this grouping, all modules having
a jumper placed on group 1 make up one group, and all modules with a jumper on group 2
make up the other group. Interchassis interlock cables must be installed between chassis.
Each module interlock group jumper block may have no more than one jumper installed at
one time.

2. Horizontal Interlock: Groups 3 and 4 are horizontal and they include only modules in the

individual chassis. With this grouping, all modules having a jumper placed on group 3
make up one group, and all modules with a jumper on group 4 make up the other group.
These groupings do not extend out of the chassis and are not affected by the interchassis
interlock cable. Each module interlock group jumper block may have no more than one
jumper installed at a time.

3. Vertical Interlock: The vertical interlock jumper position is labeled V. Placing a jumper in

this position interlocks all modules in the same slot location in other chassis having a
jumper installed on the same V position. Interchassis interlock cables must be installed
between chassis. The interchassis interlock cable is a 20 position ribbon cable (4WC-03)
with a 20-pin connector for each chassis. Each module interlock group jumper block may
have no more than one jumper installed at a time.

6.2

Alarm Jumper Installation

Determine B alarm Enable or Disable before installing module. Modules are shipped with the
jumper strap placed in the ALMB position as shown in

Figure 4-7

. In this position the B Alarm

is enabled. To disable the B Alarm move the jumper to ALMB.

Figure 4-7. Jumper Strap and B Alarm Time Delay Setting Location

1634-A

+

+

+

+

+

+

+

0

3

4

C

SW1

1 2 3 4 V

ALMB

ALMB

X.21 PATCHSWITCH

16 POSITION

A ALARM SWITCH

B ALARM

ENABLE/DISABLE

JUMPER

INTERLOCK

JUMPER