ADCP-50-304 • Issue 19 • June 1999 • Section 6: Installation

Page 6-4
© 1999, ADC Telecommunications, Inc.

Figure 6-2. Data Converter Module

1.6

Control Module DIP Switch Settings

When PatchSwitch equipment is configured for serial remote control, the chassis address must
be selected on each control module. For dc pulse control, the chassis address is ignored. Each
CM contains a four-position DIP switch to identify its chassis address. Bit positions 1 through 4
on the DIP switch are set to an identifying address assigned to that chassis during the
installation of the PS chassis system.

Caution: Make certain that each chassis on a communications channel is assigned a different
(unique) identifying address in the range of 0 through 15 (000

2

through 1111

2

).