Control Identification

70444901

10

Operation Modes

General Modes of Operation

In each mode of operation, the user may press keypads

or communicate with the control to change the

displayed menu.

Power-up Mode

The control enters this mode at power-up. When

power is applied to the tumbler, the control becomes

active and will display its software version as “

XX”

(“XX” is the version number) for one second. If the

control was not powered down during a running cycle,

it will enter the Idle Mode. After the control completes

operation in the Power-up Mode it will enter Idle

Mode.

Idle Mode

The control is ready for operation in Idle Mode.

Control can display different menus depending on user

input (keypad press, opening or closing the loading

door, or PDA communication). If there is no user input

for 10 minutes, display will turn off.
While in Idle Mode the control will display the active

cycles. Anytime the control returns to Idle Mode after

a cycle has been run, the control will display the last

run cycle (except the first time the control is powered

up it will show the first cycle).
Press the up arrow ( ) to increment the cycle number.

Press the down arrow ( ) to decrease the cycle

number. If the Start (

) keypad is pressed and

either the loading door or lint door is open the control

will show “



” for five seconds or until door is

closed.
If the control is in Idle Mode, Cycle Menu is

displayed, loading and lint door closed, and the

Start (

) keypad is pressed, control will enter Run

Mode.

Run Mode

The Control enters Run Mode during a cycle

.

Display

shows machine cycle time remaining, the current cycle

type, segment and temperature. Loading and lint doors
are closed during Run Mode. Press Stop ( ) keypad

to stop cycle and enter Pause Mode. Control enters

Pause Mode if loading or lint door opens. Press
Start (

) to Rapid Advance.

Rapid Advance Mode

If the Rapid Advance Option is enabled, the user can

advance a running machine cycle by pressing the
Start (

) keypad. In a Time Dry cycle, pressing the

Start (

) keypad will decrease the remaining time

by one minute. Pressing and holding the Start (

)

keypad will decrease the remaining time by four

minutes per second until the end of the cycle.
In the Auto-Dry and Moisture Dry cycles, pressing the
Start (

) keypad will advance the cycle to the next

enabled segment. Note that Auto-Dry cycles only have

one programmable segment.

In the Cool Down segment, pressing the Start (

)

keypad will decrease the remaining time by one

minute.
When the cycle is completed, the audit counter, Total

Rapid Advance Cycles, is incremented rather than the

Total Machine Cycles audit counter. If the Rapid

Advance Option is disabled preventing a manual

Rapid Advance, the user may still execute a Rapid

Advance using the PDA or PC. Refer to PC and PDA

Application User Instructions for additional

information on using a PDA or PC to Rapid Advance a

cycle.

Pause Mode

If Stop ( ) keypad is pressed or the loading or lint

door is opened while in Run Mode, control enters

Pause Mode.
If the door was opened to enter Pause Mode, the

control will show “



” until the door is closed or

Pause Mode is exited. If the door is closed, the control

will show “



” for one second followed by



” for one second as well as flash the

Start (

) keypad LED one second on/one second

off.
If the Stop ( ) keypad was pressed to enter Pause

Mode and the loading door is closed, the control will

show “



” until Pause Mode is exited.

Any time “



” is shown on the control, the

Start (

) keypad LED will flash one second on/one

second off to prompt the user to restart the cycle.

Error Mode

This mode will be entered to display all fatal machine

errors.

Advertising